The amount of current that is discharged off the validation coupon is typically very small and measurement tools require micro amp resolution. Conventional ammeters are inadequate for reading small currents since the loading effect of the meter adds an error value to the reading. The ZRA overcomes this loading effect and provides an extremely precise and accurate indication of protective current.