Search

  • TEST STATION CP ALUMINUM 7-TERM 1-1/4" THREADED c/w BACK PANEL TESTOX MODEL 813-7

    Code: 813TS
    AVAILABLE
    Quebec Online Orders Not Available
  • REFERENCE ELECTRODE 1-1/4" x 8 "FLAT TIP TINKER & RASOR 8A

    Code: 8A
    AVAILABLE
    Quebec Online Orders Not Available
  • REFERENCE ELECTRODE 1-1/4" x 9" POINTED TIP TINKER & RASOR 8B

    Code: 8B
    AVAILABLE
    Quebec Online Orders Not Available
  • REEL WIRE MODEL 90 NO WIRE INCLUDED CORE ONLY M.C. MILLER 30104

    Code: 90
    AVAILABLE
    Quebec Online Orders Not Available
  • RMU AC/DC COUPON ADAPTER C/W 10 ohm SHUNT RESISTOR

    Code: A04060296A1
    AVAILABLE
    Quebec Online Orders Not Available
  • RMU3-G CELLULAR ANTENNA ONLY A15000GTX30

    Code: A15000GTX31
    AVAILABLE
    Quebec Online Orders Not Available
  • MOBILTEX TEST STATION SHIELD FOR USE WITH RMU1

    Code: A20100RMU11
    AVAILABLE
    Quebec Online Orders Not Available
  • PRIMER ROYSTON A-51 PLUS US GALLON CAN ROSKOTE MASTIC LOT #

    Code: A511U
    AVAILABLE
    Quebec Online Orders Not Available
  • AC COUPON ACC2-1-05 1cm˛ 5m #12/7 STR RWU 90 GREEN

    Suitable for use with both new build and existing structures, the ACC2-1 is buried adjacent to the target pipeline. Installation can be completed quickly and efficiently, since the ACC2-1 is small enough to be positioned within a hand excavated or hydro-vac hole. Once a connection to the pipeline is established, AC current flow is measured with a standard multimeter to give a quick and accurate indication of induced current on the pipeline. These recorded values are sufficient to give operators the information they need, to determine whether AC mitigation is required and where it is required. Our strategically placed distribution hubs can dispatch in-stock ACC2-1 probes at short notice to any project in the world.

    Features and Benefits

    • Reduces owner/operator risk by allowing regular monitoring and preemptive action, to mitigate potentially hazardous AC current.
    • Validates the effectiveness of existing mitigation measures and provides regulators with historical and current operating data.
    • Cost-effective, easy hydro-vac or hand excavation installation in native backfill.
    • Compatible with remote monitoring and data recording hardware.
    • Suitable for installation with most new and existing test stations.
    Code: ACC2105
    AVAILABLE
    Quebec Online Orders Not Available
  • AC COUPON ACC2-1-10 1cm˛ 10m #12/7 STR RWU 90 GREEN SN

    Suitable for use with both new build and existing structures, the ACC2-1 is buried adjacent to the target pipeline. Installation can be completed quickly and efficiently, since the ACC2-1 is small enough to be positioned within a hand excavated or hydro-vac hole. Once a connection to the pipeline is established, AC current flow is measured with a standard multimeter to give a quick and accurate indication of induced current on the pipeline. These recorded values are sufficient to give operators the information they need, to determine whether AC mitigation is required and where it is required. Our strategically placed distribution hubs can dispatch in-stock ACC2-1 probes at short notice to any project in the world.

    Features and Benefits

    • Reduces owner/operator risk by allowing regular monitoring and preemptive action, to mitigate potentially hazardous AC current.
    • Validates the effectiveness of existing mitigation measures and provides regulators with historical and current operating data.
    • Cost-effective, easy hydro-vac or hand excavation installation in native backfill.
    • Compatible with remote monitoring and data recording hardware.
    • Suitable for installation with most new and existing test stations.
    Code: ACC2110
    AVAILABLE
    Quebec Online Orders Not Available
  • AC COUPON ACC2-1-15 1cm˛ 15m #12/7 STR RWU 90 GREEN

    Suitable for use with both new build and existing structures, the ACC2-1 is buried adjacent to the target pipeline. Installation can be completed quickly and efficiently, since the ACC2-1 is small enough to be positioned within a hand excavated or hydro-vac hole. Once a connection to the pipeline is established, AC current flow is measured with a standard multimeter to give a quick and accurate indication of induced current on the pipeline. These recorded values are sufficient to give operators the information they need, to determine whether AC mitigation is required and where it is required. Our strategically placed distribution hubs can dispatch in-stock ACC2-1 probes at short notice to any project in the world.

    Features and Benefits

    • Reduces owner/operator risk by allowing regular monitoring and preemptive action, to mitigate potentially hazardous AC current.
    • Validates the effectiveness of existing mitigation measures and provides regulators with historical and current operating data.
    • Cost-effective, easy hydro-vac or hand excavation installation in native backfill.
    • Compatible with remote monitoring and data recording hardware.
    • Suitable for installation with most new and existing test stations.
    Code: ACC2115
    AVAILABLE
    Quebec Online Orders Not Available
  • AC COUPON ACC2-1-20 1cm˛ 20m #12/7 STR RWU 90 GREEN

    Suitable for use with both new build and existing structures, the ACC2-1 is buried adjacent to the target pipeline. Installation can be completed quickly and efficiently, since the ACC2-1 is small enough to be positioned within a hand excavated or hydro-vac hole. Once a connection to the pipeline is established, AC current flow is measured with a standard multimeter to give a quick and accurate indication of induced current on the pipeline. These recorded values are sufficient to give operators the information they need, to determine whether AC mitigation is required and where it is required. Our strategically placed distribution hubs can dispatch in-stock ACC2-1 probes at short notice to any project in the world.

    Features and Benefits

    • Reduces owner/operator risk by allowing regular monitoring and preemptive action, to mitigate potentially hazardous AC current.
    • Validates the effectiveness of existing mitigation measures and provides regulators with historical and current operating data.
    • Cost-effective, easy hydro-vac or hand excavation installation in native backfill.
    • Compatible with remote monitoring and data recording hardware.
    • Suitable for installation with most new and existing test stations.
    Code: ACC2120
    AVAILABLE
    Quebec Online Orders Not Available